The Indentron Series hardness testers feature an innovative cantilevered indenter configuration that eliminates frictional inconsistencies typical of competitive testing systems. These systems comply with ASTM E-18.
Using precision dead weights; the Indentron system ensures accurate and repeatable measurements. The dead weights are used for both the major load and the preload. Automation in the timing reduces the variation introduced by the flow of the material under load. If the operator inadvertently over loads or under loads the preload; the Indentron system prevents the test from being performed.
The indenter design is ideal for testing inside diameters and recesses; often impossible with more traditional hardness testers. Inside diameters as small as 1-1/2-inches can be tested with the standard indenter. Optional indenters can test diameters as small as 1/2-inch. Operators can test close to vertical surfaces; to within 1/4-inch with the standard indenter and up to 3/32-inch with optional special indenters. Testing is fast; accurate and there are fewer broken diamonds due to an outstanding viewing area.
Two models of the Indentron Series are available- the basic 500 Series and the advanced 600 Series. The 500 Series can be supplied for Regular or Superficial testing while the 600 Series can be supplied for Regular; Superficial or combination testing methods.
The Indentron 600 Series features an advanced digital electronics and display panel. Averaging of 2-99 tests; hardness scale conversion; round correction; minimum thickness and time at load are advanced features supplied standard on the 600 Series.
An RS232 output can be used to produce X-Bar/R Charts; histograms or integrate to a personal computer with our DataView application software for more detailed analysis. Tolerances may be applied for Pass/Fail or Go/No Go results.
Indentron Series can be supplied with vertical testing capacities of 10- or 15-inches.
Indentron Features and Benefits
Virtually Friction-Free Operation
The only contact points in the load system are a set of bearings at the end of the lever beam carrying the major load and a leaf spring at the end of the lever beam carrying the minor load.
Dead Weights for Full Load and Preload
Most competitive testers use dead weights for the full load due to their accuracy; but use springs to apply the preload. Dead weights are used on the Indentron Series for both full load and preload due to their excellent accuracy and stability under a wide range of conditions.
Full Load Is Applied Precisely at Preload
Automation in the timing reduces the variations introduced by the flow of the material under load.
Preload Error Monitoring
The system prevent the operator from completing a test if the preload is over- or under-applied.
Indentron Features and Benefits
Virtually Friction-Free Operation
The only contact points in the load system are a set of bearings at the end of the lever beam carrying the major load and a leaf spring at the end of the lever beam carrying the minor load.
Dead Weights for Full Load and Preload
Most competitive testers use dead weights for the full load due to their accuracy; but use springs to apply the preload. Dead weights are used on the Indentron Series for both full load and preload due to their excellent accuracy and stability under a wide range of conditions.
Full Load Is Applied Precisely at Preload
Automation in the timing reduces the variations introduced by the flow of the material under load.
Preload Error Monitoring
The system prevent the operator from completing a test if the preload is over- or under-applied.

X5 Fisherbrand PTFE Stopper, Flask Stopper Size (U
Traceable 99M/59S Timer with Auto Shut-Off
Corning™ Pipettes sérologiques à usage unique,
Compteur de colonies Scan 300
IKA™ Tige de support en acier inoxydable
Mélangeur à immersion Digital Ultra-Turrax™
Mesh basket, Mask 8x8x1 mm, (WxDxH) 150x150x150mm
HOMOGENISER, BOROSILICATE GLASS MORTAR PTFE PESTLE
Eppendorf Xplorer™, monocanal, variable, 1 à 20 μl, gris clair
x24 Fisherbrand 240ml WM clear glass bottle, Pulp/
X10 1L Bécher, forme haute, verre borosillicaté 3.
X50 LAME VERRE 76X26MM EP 0.8-1MM
LABJACK,FISHERBRAND,ALUMINIUM
IKA™ Support de plaque R1827
COMPTE-GOUTTES PTFE 25 ML
FLACON PTFE 150ML
RETSCH Tamis de test en acier inox, 200 x 25 mm (dia. x H), porosités en micromètres, ISO 3310/1
Fisherbrand PTFE Stirrer Shaft, Plain, Exposed End
Temperature Data Logger, TraceableGO™ Wirele
X882 Flacon à vis,1.75mL,fond plat,forme haute,ver
Propeller-Rührblatt, mit 4 Flügel 45°, für Schaft
Gilson™ Pointes de filtre PIPETMAN™ Tipack™
Aperçu: GAP-LINE - Postes de travails à flux laminaire destinés aux matières dangereuses
X24 Fisherbrand 120ml NM clear glass type3 Boston
Acryl Pipettenstation für 4 Pipetten
X72 Flacon Fisherbrand,250ml,HDPE,Ambré,Col Etroit
X100 Tubes 2 ml, billes silice, céramique et verre
20mm Crimping Head for Flip Top/Flip Off Seals
MORTIER ELVEHJEM 2ML L'UNITE
CHRONEMOTRE JUMBO DIGIT
Spectrophotomètre NanoPhotometer C40
IKA™ HBC 5 Basic
x180 Fisherbrand 500ml WM natural HDPE bottle, PE
X10 Fisherbrand PTFE Stirrer Blade, Square End 76x
SUPPORT POUR 39 LAMES
Temperature probe (PT100, A Class, 400 C) for RT2
Batterie 6 chauffe-ballons Macro-KJELDAHL
TEST TUBE RACK ALUMINIUM Z- PATTERN WITH FIVE 