Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the welaunch-framework domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woo-ajax-add-to-cart domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-catalog-mode domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the antispam-bee domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the forminator domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the updraftplus domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: La fonction _load_textdomain_just_in_time a été appelée de façon incorrecte. Le chargement de la traduction pour le domaine astra a été déclenché trop tôt. Cela indique généralement que du code dans l’extension ou le thème s’exécute trop tôt. Les traductions doivent être chargées au moment de l’action init ou plus tard. Veuillez lire Débogage dans WordPress (en) pour plus d’informations. (Ce message a été ajouté à la version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114
Techne Thermocycleur à gradient 5PrimeG - AMS Labo

AMS Labo

TECHNE

Techne Thermocycleur à gradient 5PrimeG

UGS 12688885 Catégorie

Permet d’optimiser les températures de recuit en une seule expérience grâce une large plage de gradient linéaire comprise entre 19 à 29°C. Le thermocycleur à gradient Techne™ 5PrimeG offre de hautes performances, un débit élevé et une flexibilité maximale.

UGS 12688885 Catégorie

Le large gradient linéaire d’une amplitude de 29°C permet d’optimiser les températures d’hybridation en une seule expérience
La fonction de calcul du gradient affiche la température pour chacune de 12 colonnes, facilitant ainsi la reproduction des conditions thermiques
Interface à écran tactile couleur (VGA de 3,5 po avec affichage graphique) pour une configuration rapide des programmes
Les programmes peuvent être transférés entre les instruments via une connexion USB ou vers un PC
Options de bloc : 96 x 0,2 ml (compatible avec les plaques avec et sans jupe), 60 x 0,5 ml, 384 puits et Combi-Block (33 x 0,2 ml et 33 x 0,5 ml)
La mémoire interne peut contenir jusqu’à 1000 programmes, avec un stockage illimité disponible sur clé USB
Gain d’espace et faible encombrement
Redémarrage automatique en cas de coupure de courant
Pression du couvercle chauffant réglable
Exigences de puissance électrique : 100/230 V 50/60 Hz, 155 W
Spécifications :

Plage de températures des blocs : 10° à 100°C (maintien final de 4°C)
Uniformité du bloc à 55°C : <±0,3°C Précision de la température à 55°C : <±0,25°C Température du couvercle chauffant réglable : 35°C à 115°C ou éteint Fréquence maximale de chauffage : 3,4°C/sec Plage de gradient : 30° à 80°C Gradient maximum : 29°C (19°C pour 384) Gradient minimum : 1°C Type : 8 x élément Peltier/bloc L x l x H : 420 x 240 x 240 mm Poids : 9,4kg