Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the welaunch-framework domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woo-ajax-add-to-cart domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-catalog-mode domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the antispam-bee domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the forminator domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the updraftplus domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: La fonction _load_textdomain_just_in_time a été appelée de façon incorrecte. Le chargement de la traduction pour le domaine astra a été déclenché trop tôt. Cela indique généralement que du code dans l’extension ou le thème s’exécute trop tôt. Les traductions doivent être chargées au moment de l’action init ou plus tard. Veuillez lire Débogage dans WordPress (en) pour plus d’informations. (Ce message a été ajouté à la version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114
IKA™ Photo bioreacteur Algaemaster 10 control - AMS Labo

AMS Labo

IKA

IKA™ Photo bioreacteur Algaemaster 10 control

UGS 16208471 Catégorie Étiquettes , , , ,

Le photo-bioréacteur Algaemaster 10 control est un équipement parfaitement conçu pour permettre aux scientifiques de trouver
et recréer les conditions environnementales idéales de culture des organismes phototrophes tels que les micro-algues.
Ces derniers suscitent un intérêt croissant pour la découverte de médicaments dans l’industrie pharmaceutique.

UGS 16208471 Catégorie Étiquettes , , , ,

Composants principaux :
Cuve de réacteur à double paroi de 10 litres
À l’aide des raccords vissés Quickfit, un thermostat IKA peut être facilement raccordé à la cuve. Lors de l’utilisation d’une sonde de température ou pH, un volume minimum de 6 litres est nécessaire

Agitation:
La plage de vitesse d’agitation va de 10 á 100 tr/min. La tige d’agitation est revêtue de PTFE. Les pièces de l’hélice sont réglables en hauteur. La tige d’agitation est ainsi polyvalente, puisqu’elle peut créer différents mouvements ondulés en fonction du type d’échantillon.

Compris dans la livraison:
Cuve de réacteur à double enveloppe de 10 l avec raccords rapides
Couvercle fabriqué en Ultem®
Unité de contrôle
2 panneaux lumineux à LED
Sonde de température PT 100
Sonde pH
Disperseur-diffuseur de gaz
Plaque de base de la cuve
Moteur d’agitateur et tige d’agitation avec deux hélices à hauteur réglable

Contenu de la livraison
Algaemaster 10 control
Algaemaster 10 controller
Reactor vessel incl. lid, lock, motor coupling and base plate
Motor
2 LED panels
Gas intake tube
Hoses
pH probe
temperature sensor