Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the welaunch-framework domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woo-ajax-add-to-cart domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-catalog-mode domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the antispam-bee domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the forminator domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the updraftplus domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114

Notice: La fonction _load_textdomain_just_in_time a été appelée de façon incorrecte. Le chargement de la traduction pour le domaine astra a été déclenché trop tôt. Cela indique généralement que du code dans l’extension ou le thème s’exécute trop tôt. Les traductions doivent être chargées au moment de l’action init ou plus tard. Veuillez lire Débogage dans WordPress (en) pour plus d’informations. (Ce message a été ajouté à la version 6.7.0.) in /home/dcjctnx/www/wp-includes/functions.php on line 6114
Four à allumage rapide - AMS Labo

AMS Labo

NABERTHERM

Four à allumage rapide

UGS 15968270 Catégorie

Idéal pour simuler les procédés traditionnels d’allumage rapide jusqu’à une température d’allumage maximale de 1300°C. Les ventilateurs de refroidissement hautes performances, à faible masse thermique et puissants permettent de réaliser des cycles de maintien du froid pendant une durée allant jusqu’à 35 minutes, avec une température d’ouverture d’environ 300°C.

UGS 15968270 Catégorie

Température maximale : 1300°C
Modèle très compacte
Tubes quadrillés en céramique comme support de charge
Chauffage du sol et du couvercle
Commande de deux zones, partie inférieure et couvercle
Ventilateurs de refroidissement intégrés, programmables pour accélérer le refroidissement de la charge, y compris le refroidissement du boîtier
Ouverture programmable du couvercle d’environ 60 mm pour assurer un refroidissement plus rapide sans activer le ventilateur
Thermocouple de type S pour les zones supérieure et inférieure
Roulettes pour faciliter le déplacement du four
Application définie dans les limites des consignes d’utilisation
Logiciel NTLog Basic pour régulateur Nabertherm : enregistrement des données relatives aux processus avec une clé USB